Note: the Alarm Relay will reset on a ‘silence alarms’ signal from the control panel. AlarmSense Manual Call Point The AlarmSense Manual Call Point (EN54), part no. , is supplied with a backboxfor surface mounting. The call point is File Size: KB. The AlarmSense Manual Call Point has been designed to operate on a loop of AlarmSense compatible two wire fire alarm systems. An alarm is initiated by pressing the resettable element. The manual call point signals to the Control and Indicating Equipment using zener voltages. An alarm status is indicated through the rotation of the resettable element. The manual call point signals to the Control and Indicating Equipment using zener voltages. An alarm status is indicated through the rotation of the resettable element, displaying yellow and black indication bars and a solid red LED. The manual call point can be easily reset from the front using the supplied reset key. Key Features: Resettable operating element; Easy access, (Inc VAT): £
The manual call point can be easily reset from the front using the supplied reset key. AlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires, making installation quicker and less expensive. AlarmSense Manual Call Point, surface. Part No. APO. Certified to EN54 Part 11 (LPCB). Supplied with a non-breaking plastic resettable element. Suitable for use with C-TEC's CFP AlarmSense range of Zone Two-Wire Fire Panels. Includes test key and red back box. Easy access, front reset mechanism. Ergonomic reset key. Important Note: It is possible for the panel to determine if an AlarmSense™ Manual Call Point, or an AlarmSense™ detector has triggered a zone into alarm. This allows the system to be optionally set up so that, if required, the activation of a manual call point will override delays and coincidence. INSTALLATION MAINTENANCE MANUAL.
The Manual Call Point has been designed to operate on an AlarmSense two-wire loop. An alarm. Re-settable call points are cost effective as the glass does not require replacement after use. This video shows how to reset the XP95 manual call point afte. The manual call point can be easily reset from the front using the supplied reset key. Operation. When activated, the AlarmSense Manual Call Point introduces a load onto the line, which is detected by the fire control panel. The fire control panel then increases the line voltage, which activates the sounders, the manual call point load is then removed.
0コメント